PL-3700K
APL3700-KD(PFXPL37xxKD)
15"

Documentation

Support

Design Tools

Software

Certifications

Functional Specifications

Display Type
TFT Color LCD
Display Size
15"
Resolution
1,024 x 768 pixels (XGA)
Dot pitch
W0.297 x H0.297 mm [W0.01 x H0.01 in.]
Effective Display Area
W306.2 x H230.1 mm [W12.06 x H9.06 in.]
Display Colors
262,144 Colors
Backlight
CCFL (Replaceable)
Brightness Control
4 Levels (Adjusted with the software)
Contrast Control
Not applicable
Backlight Service Life
50,000 hrs. or more (continuous operation at 25℃ before backlight brightness decreases to 50% or backlight starts to blink)
Supported OS
Windows® 2000/Windows® XP/Windows® XP Embedded
CPU
Intel® Core™ Duo 2.0 GHz/Celeron® M 440 1.86 GHz
L2 Cache Memory
Intel® Core™ Duo 2.0 GHz 2 MB/Celeron® M 440 1.86 GHz 1 MB (Built in the CPU)
Main Memory
DDR2 SDRAM (PC4200), 512 MB/1 GB/2 GB (SO-DIMM socket x 2 slots)*1
Chipset
Intel® 945GME + ICH7M
Graphics Accelerator
Built in Intel® 945GME
Video Memory
64 MB or less (When using Windows®) UMA Type
Graphics
SXGA (1,280 x 1,024 pixels)
BIOS
Phoenix® TrustedCore™ BIOS
Clock Accuracy
±180 sec/month (deviation at room temperature and power is OFF)*2
Touch Panel Type
Resistive Film (analog)
Touch Panel Resolution
1,024 x 1,024
Touch Panel Service Life
1,000,000 times or more, Sweeping 100,000 times or more
Touch Panel Interface
Internal USB
No. of Key Switches
74
Key Switch type
Membrane switch
Key Switch Server Life
1,000,000 times or more
Key Switch Interface
Internal USB
Serial ATA
Serial ATA Rev. 1.0a x 2, 2.5" HDD Unit or SSD Unit
IDE
Master: CF Card Slot (Type I/II compatible) x 1, Slave: DVD Drive x 1
Serial (COM1)
RS-232C (RS-232C/422/485 switch possible, RI/+5 V switch possible), Connector: D-Sub9 (plug)
Serial (COM2)
RS-232C (RI/+5 V switch possible), Connector: D-Sub9 (plug)
Serial (COM3)
RS-232C, Connector: D-Sub9 (plug)
Serial (COM4)
RS-232C, Connector: D-Sub9 (plug)
Ethernet (LAN1)
IEEE802.3i/IEEE802.3u/IEEE802.3ab, 10BASE-T/100BASE-TX/1000BASE-T, Connector: Modular jack (RJ-45) x 1
Ethernet (LAN2)
IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack (RJ-45) x 1
USB (TYPE-A)
Conforms to USB2.0 (TYPE-A) x 5, Power Supply Voltage: DC 5 V ±5 %, Output Current: 500 mA or less, Communication Distance: 5 m or less
Video
DVI-I OUT, Connector: DVI-I 29 pin (socket) X 1*3
RAS
Input (external reset input possible): 2 points, Output 2 points, Rated Voltage: DC 12 V, Maximum Rated Current: 100 mA, Connector: D-Sub9 (socket) x 1
Sound
Speaker output, connector: mini-pin jack
CD/DVD-ROM Drive
DVD-ROM Drive/DVD Multi Drive (option)

1Available memory region is around 3.5GB.

2Depending on the operating temperature and age of unit, the clock can deviate ±300 sec/month. For systems where this level of deviation is a problem, the user should monitor and make adjustments when required.

3・ When the dual output with the front module is selected, the DVI-I can be connected to an analog RGB monitor only., ・ When connecting the Pro-face FP3000 Series to the PL-3000B Series, use the Pro-face DVI-D cable (10m) FP-DV01-100.

General Specifications

International Safety Standards
Rated Input Voltage
DC 24V
Input Voltage Limits
DC 19.2 to 28.8V
Allowable Voltage Drop
5 ms or less
Power Consumption
145 W or less
In-Rush Current
40 A or less
Voltage Endurance
AC 1,000 V, 20 mA for 1 min (between charging and FG terminals)
Insulation Resistance
DC 500 V, 10 MΩ or more (between charging and FG terminals)
Surrounding Air Temperature
5 to 50 °C: with HDD, 0 to 50 °C: without HDD*4
Storage Temperature
-20 to 60 °C (-4 to 140 °F)
Ambient Humidity
10 to 90 % RH (Not condensing, wet bulb temperature: 39 ℃ or less. Wet bulb temperature with HDD/DVD drive: 29 ℃ or less)
Storage Humidity
10 to 90 % RH (Wet bulb temperature: 39 ℃ or less - no condensation.)
Dust
0.1 mg/m³ or less (non-conductive levels)
Pollution Degree
For use in Pollution Degree 2 environment
Atmosphere
Free of corrosive gases
Air Pressure (altitude range)
800 to 1,114 hPa (2,000 m [6,561ft.] above sea level or less)
Vibration Resistance
With HDD: 10 to 57 Hz Single amplitude 0.075 mm [0.003 in.], 57 to 150 Hz Fixed acceleration 9.8 m/s², X, Y, Z directions for 10 cycles (80 min), Without HDD: IEC/EN61131-2 compliant, 5 to 9 Hz Single amplitude 3.5 mm [0.14 in.], 9 to 150 Hz Fixed acceleration 9.8 m/s², X, Y, Z directions for 10 cycles (100 min)*5
Noise Immunity
Noise Voltage: 1,500 Vp-p, Pulse Duration: 50 ns, 500 ns, 1 μs, Rise Time: 1 ns, (via noise simulator)
Electrostatic Discharge Immunity
Contact Discharge Method: 6 kV (IEC/EN61000-4-2 Level 3)
Grounding
Functional grounding: Grounding resistance of 100Ω, 2mm² or thicker wire, or your country's applicable standard. (Same for FG and SG terminals)
Structure
Equivalent to IP65f NEMA #250 TYPE 4X/12 (When embedding the panel and not using the front panel USB port.)*6
Installation Configuration
Embedded panel
Cooling Method
Forced air cooling by the CPU fan
Weight Approx.
2 slot type: 13 kg [28.6 lb] or less (display unit only), 4 slot type: 14 kg [30.8 lb] or less (display unit only)
External Dimensions
2 slot type: W488 x H367 x D166 mm [W19.21 x H14.45 x D6.54 in.], 4 slot type: W488 x H367 x D218 mm [W19.21 x H14.45 x D8.58 in.]
Panel Cut Dimensions
W441.5 x H315.5 mm [W17.38 x H12.34 in.], Panel thickness area: 1.6 to 10 mm [0.06 to 0.39 in.]*7

45 to 45 ℃ during DVD data writing or with a battery.

5The Vibration Resistance is 1.96m/s² during DVD drive unit's read/write running.

6The front face of the GP unit, installed in a solid panel, has been tested using conditions equivalent to the standards shown in the specification. Even though the GP unit's level of resistance is equivalent to these standards, oils that should have no effect on the GP can possibly harm the unit. This can occur in areas where either vaporized oils are present, or where low viscosity cutting oils are allowed to adhere to the unit for long periods of time. If the GP's front face protection sheet becomes peeled off, these conditions can lead to the ingress of oil into the GP and separate protection measures are suggested., Also, if non-approved oils are present, it may cause deformation or corrosion of the front panel's plastic cover. Therefore, prior to installing the GP be sure to confirm the type of conditions that will be present in the GP's operating environment., If the installation gasket is used for a long period of time, or if the unit and its gasket are removed from the panel, the original level of the protection cannot be guaranteed. To maintain the original protection level, be sure to replace the installation gasket regularly.

7Regarding dimensional tolerance, everything +1/-0 mm [+0.04/-0 in.] and R in angle are below R3 [R0.12 in.].

External Dimensions / Interfaces / Panel Cut-out